Showing results: 46 - 60 of 108 items found.
-
AFJ Instruments
Through different ways of coupling between luminaries and humans, a level of exposure of a person to electromagnetic fields can be derived. One part of the exposure is based on capacitive coupling between lighting equipment and person. This creates induced internal electric field that must be evaluated using an EMI receiver and a Van Der Hoofden test head.
-
XF1 set -
Langer EMV-Technik GmbH
The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.
-
Schwarzbeck Mess Elektronik
Active Electric Field Probe with Biconical Elements9 kHz - 300 MHz12 µV/m - 65 V/mconst. antenna factor typ. 46 dB/m high symmetrybuilt in rechargeable batteryThe switchable preamplifier improves the antenna factor to 20 dB/m.
-
Peritec Corp.
The EMI tester automatically measures the noise distribution of the electric field and the magnetic field radiated from electronic equipment with high accuracy.・ Even if PCB and IC parts have complicated bumpy shape and surface. The movable assembly can automatically trace them.・ EMI noise distribution is expressed as a variety of maps, such as 4D/3D/2D graphics and cross section view.
-
ALCL-40D -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Best sensor for micro ampere current measurements.*Super high accurate sprit type ZCT sensor.*High sensitivity and least affection from external magnetic field. (less than 10μA for 400A nearby conductor)*For leakage current measurements of arrester.*Stable measurements under high electric field and strong magnetic field.
-
AET Associates, Inc.
X-ray and radioactive devices developed by AET, are widely utilized for medical, industrial and research use. The Compact Pulse X-ray Source can accelerate electron beams in a high-gradient electric field, to produce X-rays. Dose Calibrators are utilized for radioactive examinations and treatments in the medical industry.
-
A.H.Systems, Inc.
Our Monopole Antennas provide superior performance in electric field measurements. The Active Monopole Antenna can drive any receiver with 50W input impedance and will perform FCC, MIL-STD and TEMPEST tests. The passive rod is used for transmitting, to perform shielding effectiveness and immunity testing.
-
EMCTEST
Open Test Sites or OATS (Open Area Test Sites) are the most simple and cost effective ambient of measuring for Electric field emission of test objects within frequency range 30 MHz – 3000 MHz . Gtemcell offers sites for 10m and 30m measuring distance.
-
HIGHVOLT Prüftechnik Dresden GmbH
Electrostatic precipitators are used for clean process and exhaust gases, for example, in the cement and building materials industry, in steel mills, in conventional power plants, and in waste incineration plants. The dust particles are discharged electrostatically charged by a spray electrode, deflected by a DC electric field and deposited on the electrode.
-
Greenlee Tools
*Warns of high voltage electric fields using WAVi technology - Work Area Voltage Indication*Visual and audible warning indicates the location of energized fields in a red-yellow-green sequence*Detectors communicate with each other within a mesh network*Remotely control detectors through the Lookout mobile app*Battery life of up to 500 hours in Monitor mode and up to 8 hours in Alert mode*Durable water-resistant housing
-
Meggitt
From the International Space Station to a simple electronic compass, we can provide a solution to meet your magnetic semiconductor needs. The F.W. Bell® product line was founded in 1944. Since then we have been a pioneer in developing instrumentation to measure electric current and magnetic fields.
-
ESM-100 -
Maschek Elektronik
The 3D H/E fieldmeter ESM-100 is a patented, unique hand held measuring instrument. It can easily measure electric and magnetic alternating fields simultaneously, independent of their direction, and at one point. With this piece of equipment it is possible for anybody, to carry out quick, professional and error-free measurements, right from the beginning
-
MQB3 -
The Eastern Specialty Company
Apply true three phase voltage and current to electric meters, enabling them to be tested under all possible conditions that may be encountered in the field with TESCO’s Three Phase Meter Qualification Board (MQB3).
-
MEWOI Electronics Co.,ltd
Earth Resistance Tester is widely applied in ground resistance measurement, loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industrial electrical equipment, etc. When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, which means safer and faster.
-
HS6-DIFF-1000XMEGS-W -
TEAM SOLUTIONS, INC.
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEGS EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.